    so a house with 120v@200A will have a capacity of 24kw. I am really curious about how is that divided between heating devices. I can tell already 7-11 kw will be dedicated for EV charging if existed

    • Admiral Patrick@dubvee.org
      link
      fedilink
      English
      arrow-up
      8
      ·
      edit-2
      2 years ago

      It’s closer to 48kw. North American (residential) power is weird. lol.

      We use what’s called split phase where basically you have three wires coming into your electric panel: two “hot” ones each carrying 120v and one ground.

      The breaker box is staggered so that every other slot is powered by one or the other 120v inputs. To get 240v for large appliances, we use big, double-breakers which connect both of the 120v inputs together.

      The rest of the 120v circuits are staggered across the two 120v inputs. e.g. If one of the two “hot” cables was disconnected, roughly half the outlets in your house would still work.

          • Maëlys@slrpnk.net
            link
            fedilink
            arrow-up
            2
            ·
            edit-2
            2 years ago

            yea cause that sounds like industrial scale capacity!

            nonetheless, it helps to have a thermally isolated residence to avoid warmth dissipation